Authorize autosync – HP NonStop G-Series User Manual
Page 35
Installation
HP AutoSYNC User’s Guide—522580-016
2-7
Authorize AutoSYNC
The following is displayed in the EMS log:
Appendix A, Operations and Management
describes further details on configuring and
determining the status of the monitor process.
Authorize AutoSYNC
To perform scheduled synchronizations, the ASYSYNCP process must be granted the
correct access rights. Authorization is the operation that confers these rights by
designating a user ID as the Authorizer. Only users that are “under” the Authorizer can
schedule synchronizations. See
on page 4-2 for details.
By default, the Authorizer is the user ID of the monitor process.
To designate the Authorizer explicitly, log on as the desired user ID and use the
command. The command sets the ownership of the ASYSYNCP process
to the Authorizer through the PROGID file attribute.
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Starting Version
1.6.1 - 14SEP2004
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Message
AutoSYNC License Information
Valid from date: None
Expiration date: Oct 15 2004
CPU model: Any
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Message
AutoSYNC Global Settings
AutoSYNC ON
SYNCcompress OFF
SYNCrecover ON
SYNCoverIP OFF
SYNCTCPprocesses $ZTC0
EMSCollector $0
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Started
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY SYNCUSER table cached.
Table entry count = 1.
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY Backup started, cpu 3
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0423
started. User USER.SALLY, Dest
\SIERRA, Batch 0
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0424
started. User USER.SALLY, Dest
\SIERRA, Batch 2
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0425
started. User USER.SALLY, Dest
\SIERRA, Batch 3
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process $X0426
started. User USER.SALLY, Dest
\SIERRA, Batch 1
15:55 10JUN04 128,06,346 AutoSYNC ASYSYNC $X0426 Error 14 accessing
destination monitor \RSYS.$ZASY. User
DEVOF.JOHANNEC, Dest \RSYS, Batch 1
15:55 10JUN04 128,04,355 AutoSYNC Monitor $ZASY ASYSYNC process
\SYS.$X0426 stopped. User
DEVOF.JOHANNEC, Dest \RSYS, Batch 1
Caution. All monitor status and error messages are written to its hometerm. The default
hometerm is $0, which is the default EMS collector.