HP NonStop G-Series User Manual
Page 258
Error Messages
HP AutoSYNC User’s Guide—522580-016
D-10
Critical event messages
432
Cause. A source or destination ASYSYNC process detected a version mismatch. The
process that failed and the starting process, either the AutoSYNC monitor or the
source ASYSYNC process if the destination ASYSYNC process failed, have different
versions.
Effect. The ASYSYNC process that detected the version mismatch abends.
Recovery. Install the same AutoSYNC version on the source and destination systems.
433
Cause. The referenced product is licensed for a maximum number of logical NSK
processors (MAXCPUS). The number of active processors exceeds the license
maximum. This message applies to NonStop Integrity servers only.
Effect. Messages are written to the EMS log and to the home terminal.
Recovery. Contact the license manager requesting a valid license with sufficient
number of logical processors. Please provide your system serial number and order
number.
600
Cause. An unauthorized user attempted to start the monitor process.
Effect. The monitor process is not started.
Recovery. Start the monitor process with an authorized user id.
701
Cause. A required program object file is missing from the product subvolume.
Effect. The process abends.
Recovery. Install the missing object file and re-execute the program.
ASYSYNC version mismatch
System contains more logical processors than permitted by
license.
Monitor start unauthorized
Product object missing