beautypg.com

Setting the controller id, Setting hard addressing, Example command and response – HP StorageWorks 1000 Modular Smart Array User Manual

Page 36: Basic command, Command options

background image

36

Using the CLI

Example command and response

Setting the controller ID

This command can be used to assign a unique name to each controller installed in the MSA.

NOTE:

In OpenVMS environments, a unique identifier must be assigned to each MSA controller. The

value must be numeric.

Basic command

set this_controller_id

-or-

set other_controller_id

Command options

identifier

—the user-defined ID for the controller. The ID can be up to 230 alphanumeric characters

or a decimal number in the range of 0 though 65535. If spaces are included in the name, quotation

marks are required.

Example command and response

CLI> set this_controller_id MSA-1

Controller identifier MSA-1 created.

Setting hard addressing

To enable or disable Fibre Channel Arbitrated Loop hard addressing on an MSA controller:

Basic command

set this_controller_hard_address

Command options

enable|disable

—enables or disables hard addressing on the controller.

loop_id

—a decimal number between 0 and 125 to assign the loop identifier.

Example command and response

CLI> set this_controller_hard_address enable 1

Hard Addressing is enabled.

Loop ID = 1, ALPA = 0xE8

CLI> set globals expand_priority=medium

rebuild_priority=medium system_name=”MSA-1”

read_cache=50 write_cache=50

Global

Parameters:

System Name:

MSA-1

Rebuild Priority:

medium

Expand Priority:

medium

Total Cache:

256MB

50% Read Cache:

256MB

50% Write Cache:

256MB