Using the CLI
Example
show connections
command and response
NOTE:
Use the
show connections
command to verify that all connections to the MSA are recognized
and defined, including the profile type.
CLI> show connections
Connection Name:
Host WWNN = 11111111-11111111
Host WWPN = 22222222-22222222
Profile Name = Windows
Unit Offset = 0
Controller 1 Port 1 Status = Online
Controller 2 Port 1 Status = Offline
Connection Name:
Host WWNN = 33333333-33333333
Host WWPN = 44444444-44444444
Profile Name = Windows
Unit Offset = 0
Controller 1 Port 1 Status = Online
Controller 2 Port 1 Status = Offline
Example
show preferred_path
command and response
CLI> show preferred_path
Controller 1 (this_controller) is the current optimal path for these units;
0,1,4,5
Controller 2 (other_controller) is the current optimal path for these units;
2,3,6,7
Implicit (automatic load-based) LUN ownership changes are currently
DISABLED.
Controller 1 (this_controller) is the explicit power-up path for these
units; 0,1,4,5
Controller 2 (other_controller) is the explicit power-up path for these
units; 2,3,6,7