beautypg.com

Example, Show connections, Show preferred_path – HP StorageWorks 1000 Modular Smart Array User Manual

Page 24

background image

24

Using the CLI

Example

show connections

command and response

NOTE:

Use the

show connections

command to verify that all connections to the MSA are recognized

and defined, including the profile type.

CLI> show connections

Connection Name:

Host WWNN = 11111111-11111111

Host WWPN = 22222222-22222222

Profile Name = Windows

Unit Offset = 0

Controller 1 Port 1 Status = Online

Controller 2 Port 1 Status = Offline

Connection Name:

Host WWNN = 33333333-33333333

Host WWPN = 44444444-44444444

Profile Name = Windows

Unit Offset = 0

Controller 1 Port 1 Status = Online

Controller 2 Port 1 Status = Offline

Example

show preferred_path

command and response

CLI> show preferred_path

Controller 1 (this_controller) is the current optimal path for these units;

0,1,4,5

Controller 2 (other_controller) is the current optimal path for these units;

2,3,6,7

Implicit (automatic load-based) LUN ownership changes are currently

DISABLED.

Controller 1 (this_controller) is the explicit power-up path for these

units; 0,1,4,5

Controller 2 (other_controller) is the explicit power-up path for these

units; 2,3,6,7