Enabling/disabling automatic path switching, Basic command, Command options – HP StorageWorks 1000 Modular Smart Array User Manual

Page 34: Example command and response

background image

34

Using the CLI

Enabling/disabling automatic path switching

NOTE:

This command is available only with active/active firmware (v6.x or later).

If implicit path changes are enabled, controller firmware will automatically determine and, as needed,

switch controller paths for units based on host request load, according to the specified preferences.

Basic command

set auto_path_change [prp=#] [mnr=#] [twp=#] [twl=#]

Command options

enable|disable

—enables or disables implicit path switching.

prp

—specify a proxied percentage (# = 51-100). This is the minimum percentage of proxied requests

required to trigger implicit path change.

mnr

—specify the minimum number of requests that must be issued to the LUN before path changes are

enabled (the number is rounded up to the next highest power of two).

twp

—specify the minimum number of minutes (0-255) to wait at power-up before changing LUN

ownership.

twl

—specify the minimum number of minutes (0-255) to wait before changing LUN ownership again

for same unit.

Example command and response

CLI> set auto_path_change disable

Implicit (automatic load-based) LUN ownership changes are currently

DISABLED.

CLI> set auto_path_change enable

Implicit (automatic load-based) LUN ownership changes are currently ENABLED.

Implicit LUN ownership change preferences are as follows:

Minimum % of proxied requests to trigger implicit path change..: 75%

Minimum number of requests to LUN before path change enabled...: 65536

Minimum time to wait before changing ownership after power-up..: 30 minutes

Minimum time between ownership changes for LUN.................: 30 minutes

CLI> set auto_path_change twp=15

Implicit (automatic load-based) LUN ownership changes are currently ENABLED.

Implicit LUN ownership change preferences are as follows:

Minimum % of proxied requests to trigger implicit path change..: 75%

Minimum number of requests to LUN before path change enabled...: 65536

Minimum time to wait before changing ownership after power-up..: 15 minutes

Minimum time between ownership changes for LUN.................: 30 minutes