Defining a shared uplink set – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 76

Network management 76
Field name
Description
Network Name
Displays the name of the associated networks
VLAN ID
Displays the VLAN ID number
Native
Select whether native VLAN is enabled (checked) or disabled
(unchecked).
Smart Link
Select whether Smart Link is enabled (checked) or disabled (unchecked).
Private Network
Select to designate (checked) or not to designate (unchecked) this
network as a private network.
The following table describes the available actions in the Define Shared Uplink Set screen. Clicking
another link in the pull-down menu or left navigation window causes current edits that have not been
applied to be lost.
Task
Action
Add an external port
Click the down arrow on Add Port. Select the enclosure, bay number, and
port number.
Set the Port Role to primary or
secondary
Click the down arrow in the Port Role column and select Primary or
Secondary.
Change the uplink interface
port speed or disable the port
Click the drop-down box under Speed/Duplex, and then select a setting.
Delete a port
Click the Delete icon in the Delete column of the port to be deleted.
Change connection mode
Click the down arrow in the box next to Connection Mode, and then select
Auto or Failover. For information on Connection Modes, see "Defining a
shared uplink set (on page
)."
Add an Associated Network
Right-click on the header row of the Associated Networks (VLAN tagged)
table to display a menu, and then select Add.
Enable native VLAN on the
network being defined
Select the Native checkbox. Only one network can be designated as the
native VLAN.
Enable or disable Smart Link
on the network being defined
Select the Smart Link checkbox.
Designate or do not designate
this network as a private
network
Select the Private Network checkbox.
Set a custom value for
preferred link connection
speed or maximum link
connection speed
Select the Advanced Network Settings checkbox.
Edit associated network
properties
Left-click to select an associated network, right-click to display a menu, and
then select Edit.
Delete an associated network
Left-click to select an associated network, right-click to display a menu, and
then select Delete.
Defining a shared uplink set
To define a shared uplink set:
- Integrity BL870c i2 Server-Blade Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Integrity BL860c i2 Server-Blade 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem