MSA2000 3Gb 3.5" 12-drive enclosure
Power supply LEDs
Power redundancy is achieved through two independent load-sharing power supplies. In the event of a
power supply failure, or the failure of the power source, the storage system can operate continuously on a
single power supply. Greater redundancy can be achieved by connecting the power supplies to separate
circuits. DC power supplies are equipped with a power switch. AC power supplies may or may not have a
power switch (model shown below has no power switch). Whether a power supply has a power switch is
significant to powering on/off.
Table 18
LEDs — HP MSA2000 3Gb rear panel
LED
Description
Definition
1
Power supply LEDs
See
2
Unit Locator
Off — Normal operation.
Blinking white— Physically identifies the expansion module.
3
SAS In Port Status
Green — Port link is up and connected.
Off — Port is empty or link is down.
4
OK to Remove
Not implemented.
5
Fault/Service Required
Amber — A fault has been detected or a service action is required.
Blinking amber — Hardware-controlled powerup or a cache flush
or restore error.
6
FRU OK
Green — Expansion module is operating normally.
Blinking green — System is booting.
Off — Expansion module is not OK.
7
SAS Out Port Status
Green — Port link is up and connected.
Off — Port is empty or link is down.
0
0
1
2
4
3
5
6 7