Is the power supply’s input power source led off – HP P2000 G3 MSA Array Systems User Manual

Page 57

background image

HP P2000 G3 iSCSI MSA System User Guide

57

Is the power supply’s Input Power Source LED off?

Is the power supply’s Voltage/Fan Fault/Service Required LED amber?

Controller failure in a single-controller configuration

Cache memory is flushed to CompactFlash in the case of a controller failure or power loss. During the write

to CompactFlash process, only the components needed to write the cache to the CompactFlash are

powered by the super-capacitor. This process typically takes 60 seconds per 1 Gbyte of cache. After the

cache is copied to CompactFlash, the remaining power left in the super-capacitor is used to refresh the

cache memory. While the cache is being maintained by the super-capacitor, the Cache Status LED flashes

at a rate of 1/10 second off and 9/10 second on.

IMPORTANT:

Transportable cache only applies to single-controller configurations. In dual controller

configurations, there is no need to transport a failed controller’s cache to a replacement controller because

the cache is duplicated between the peer controllers.

Answer

Possible reasons

Actions

No

System functioning properly.

No action required.

Yes

The power supply is not

receiving adequate power.

Verify that the power cord is properly connected and

check the power source it is connected to.

Check that the power supply FRU is firmly locked into

position.

Check the event log for specific information regarding

the fault.

Isolate the fault.

Contact an authorized service provider for assistance.

Answer

Possible reasons

Actions

No

System functioning properly.

No action required.

Yes

The power supply unit or a fan

is operating at an

unacceptable voltage/RPM

level, or has failed.

When isolating faults in the power supply, remember that

the fans in both modules receive power through a

common bus on the midplane, so if a power supply unit

fails, the fans continue to operate normally.

Check that the power supply FRU is firmly locked into

position.

Check that the power cable is connected to a power

source.

Check that the power cable is connected to the power

supply module.