beautypg.com

Disk drive leds, 13 leds — disk drive leds, 14 leds — disk drive combinations – HP P2000 G3 MSA Array Systems User Manual

Page 68

background image

68

LED descriptions

Disk drive LEDs

Table 13

LEDs — Disk drive LEDs

LED

Description

1

Fault/UID (amber/blue)

2

Online/Activity (green)

Table 14

LEDs — Disk drive combinations

Online/Activity (green) Fault/UID (amber/blue)

Description

On

Off

Normal operation. The drive is online, but it is not

currently active.

Blinking irregularly

Off

The drive is active and operating normally.

Off

Amber; blinking regularly

(1 Hz)

Offline; the drive is not being accessed. A predictive

failure alert may have been received for this device.

Further investigation is required.

On

Amber; blinking regularly

(1 Hz)

Online; possible I/O activity. A predictive failure alert

may have been received for this device. Further

investigation is required.

Blinking irregularly

Amber; blinking regularly

(1 Hz)

The drive is active, but a predictive failure alert may

have been received for this drive. Further investigation

is required.

Off

Amber; solid

1

Offline; no activity. A failure or critical fault condition

has been identified for this drive.

Off

Blue; solid

Offline. The drive has been selected by a

management application (SMU).

On or blinking

Blue; solid

The controller is driving I/O to the drive, and it has

been selected by a management application (SMU).

1

2

1

2

3.5" LFF di

s

k drive

2.5"

S

FF di

s

k drive