beautypg.com

HP Netserver L Server series User Manual

Page 23

background image

Chapter 3

Configuring Mass Storage

17

Hot Swap Subsystem SCSI Address Settings

Switches 4 and 6 determine the SCSI address setting for each shelf in the hot swap
subsystem. Table 3-2 lists the shelf SCSI address for each switch setting.

NOTE

For information on changing the SCSI address setting on the
CD-ROM drive, see the Technical Information Label on the
CD-ROM drive.

Table 3-2. SCSI Address Settings

Upper Cage

Lower Cage

Switch Settings

SCSI Address

Switch Settings

SCSI Address

3 - Off

4 - Off

6 - Off

Shelf 1 = ID 1

Shelf 2 = ID 2

Shelf 3 = ID 3

3 - Off

4 - Off

6 - On

Shelf 4 = ID 4

Shelf 5 = ID 5

Shelf 6 = ID 6

3 - Off

4 - On

6 - Off

Shelf 1 = ID 1

Shelf 2 = ID 0

Shelf 3 = ID 3

3 - Off

4 - On

6 - On

Shelf 4 = ID 4

Shelf 5 = ID 0

Shelf 6 = ID 6

3 - On

4 - Off

6 - Off

Shelf 1 = ID 9

Shelf 2 = ID 10

Shelf 3 = ID 11

3 - On

4 - Off

6 - On

Shelf 4 = ID 12

Shelf 5 = ID 13

Shelf 6 = ID 14

3 - On

4 - On

6 - Off

Shelf 1 = ID 9

Shelf 2 = ID 8

Shelf 3 = ID 11

3 - On

4 - On

6 - On

Shelf 4 = ID 12

Shelf 5 = ID 8

Shelf 6 = ID 14