User-security – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 68

Command line 68
user-security
Manage strong password validations when adding new users and specifying passwords for users.
Supported actions: help, set, show
Item Description
set user-security
Modify domain user security settings and enforce additional security requirements
for user passwords.
Syntax
set user-security StrongPasswords=
MinPasswordLength=<3-40>
Properties
StrongPasswords
(optional)
Enables or disables strong password enforcement. If enabled, then new, local
users that are created are validated against the password characteristics
specified. Valid values include: "Enabled" and "Disabled".
MinPasswordLength
(optional)
The minimum password length allowed for new passwords when adding a new
user and when changing an existing password. The default value is 3.
Examples
->set user-security StrongPasswords=Enabled
Enables strong user password enforcement
->set user-security StrongPasswords=Disabled
Disables strong user password enforcement
->set user-security MinPasswordLength=10
Modifies the minimum password length
Item Description
show user-security Display general domain user security settings.
Syntax
show user-security
Example
->show user-security
Displays strong user password settings
vcm
Reset the Virtual Connect Manager.
Supported actions: help, reset
Item Description
reset vcm
Reset the Virtual Connect Manager. A failover to the standby VCM may
also be specified (optional), if there is a standby VCM available.
IMPORTANT: Resetting the VCM causes a temporary loss in connectivity
with the Virtual Connect Manager. If failover is specified and there is a
standby VCM, users are logged off and must reconnect using the standby
VCM IP address.
Syntax
reset vcm [-failover]
Option
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem