HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 42

Command line 42
Item Description
->remove network MyNetwork
Removes a network
->remove network *
Removes all networks
Item Description
set network
Modify an existing Ethernet network.
Syntax
set network
[State=
[SmartLink=
[Private=
[ConnectionMode=
[VLanTunnel=
[PrefSpeed=
[MaxSpeed=
Parameter
NetworkName
(required)
The name of an existing network to modify
Option
Quiet (optional) Suppresses user confirmation prompts during network creation and modification.
This option is used mainly in automated scripting scenarios.
Properties
Name (optional) The new name of the network
State (optional) Enables or disables the network. Valid values are "Enabled" and "Disabled".
SmartLink
(optional)
Enables or disables the SmartLink capability for a port. Valid values include
"Enabled" and "Disabled".
NativeVLAN
(optional)
Enables or disables the network to act as a native VLAN. Valid values are "Enabled"
and "Disabled". The default value is "Disabled". This property can be configured
only if it is a applied to a shared network.
Private
(optional)
Enables or disables the network to act as a private network. Valid values are
"Enabled" and "Disabled". The default value is "Disabled".
VLanID (optional) Modifies the VLAN ID of the network if it belongs to a shared uplink set that has not
been configured.
ConnectionMode
(optional)
Specifies the connection type that is formed when multiple ports are added to the
network. Valid values include "Auto" and "Failover". The default value is "Auto".
VLanTunnel
(optional)
Enables or disables VLAN tag tunneling. If Enabled, VLAN tags are passed through
the domain without any modification. If disabled, all tagged frames are discarded.
If multiple networks are configured on any server port, this option cannot be
modified.
PrefSpeedType
(Optional)
Default connection speed for any Ethernet connection attached to this network. Valid
values include "Auto" and "Custom". "Custom" allows the user to configure the
preferred speed. The default value is "Auto".
PrefSpeed
(Required if
PrefSpeedType is
'Custom')
The connection speed for any Ethernet connection attached to this network. Valid
values range from 100Mb-10Gb in 100Mb increments.
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem