User – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 65

Command line 65
Item Description
UplinkSetName
(required)
The name of an existing shared uplink port set. "*" removes all the existing
uplink port sets from the domain.
Example
->remove uplinkset MyUplinkSet
Removes a shared uplink port set
Item Description
set uplinkset
Modify an existing shared uplink port set.
Syntax
set uplinkset
[ConnectionMode=
Parameter
UplinkSetName
(required)
The name of an existing shared uplink set to modify
Properties
Name (optional)
The new name of the shared uplink set
ConnectionMode
(optional)
Specifies the connection type that is formed when multiple ports are added to
the uplinkset. Valid values include "Auto" and "Failover". The default value is
"Auto".
Examples
->set uplinkset Blue Name=Red
Changes the name of an shared uplink set from "Blue" to "Red"
->set uplinkset Blue connectionMode=Failover
Changes the connection mode of the uplink set
Item Description
show uplinkset
Display shared uplink configurations.
Syntax
show uplinkset [
Parameter
UplinkSetName
(optional)
Name of an existing uplink port set. "*" displays a detailed view of all the
uplink port sets. If not specified, summary of all uplink port sets will be
displayed.
Examples
->show uplinkset
Displays a summary listing of all uplink sets
->show uplinkset *
Displays detailed information for all shared uplink sets
->show uplinkset MyNetwork
Displays detailed information for a specific shared uplink set
user
Manage local domain user configurations.
Supported actions: add, help, remove, set, show
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem