Firmware – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 31

Command line 31
Item Description
->set fc-connection RedProfile 2 Fabric=""
Sets a FC SAN fabric connection to "Unassigned"
->set fc-connection BlueProfile 1 Fabric=SAN_7
Changes the FC SAN fabric of an FC SAN connection
->set fc-connection BlueProfile 1 Speed=4Gb
Changes the port speed of an FC SAN connection
->set fc-connection BlueProfile 1 BootPriority=Primary
BootPort=50:06:0B:00:00:C2:62:00 BootLun=5
Changes the SAN boot priority and sets additional boot parameters
Item Description
show fc-connection
Display the FC SAN connections associated with the server profiles.
Syntax
show fc-connection
Parameter
ConnectionID
(optional)
The ID of an existing FC SAN connection. The ID format is
connections of a profile. '*' displays all the FC SAN connections existing in
the domain.
Examples
->show fc-connection
Displays all FC SAN connections existing in the domain
->show fc-connection Profile1:*
Displays FC SAN connections of a profile Profile1
->show fc-connection Profile1:1
Displays a specific FC SAN connection of profile Profile1
firmware
Display or update Virtual Connection firmware version.
Support actions: help, show, update
Item Description
show firmware
Display the current version of firmware for all interconnect modules in the domain.
Syntax
show firmware
Examples
->show firmware
Displays current version of the firmware
->show firmware *
Displays detailed listing of all firmware
Item Description
update firmware
Update the firmware on all Virtual Connect modules in the domain.
Syntax
update firmware [-quiet] URL=
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem