Page 29

Command line 29
fc-connection
Add a new Fibre Channel SAN connection to a server profile.
Supported actions: add, help, remove, set, show
Item Description
add fc-connection
Add a new FC SAN connection to an existing server profile.
Syntax
add fc-connection
[Speed=
[AddressType=Factory-Default|User-Defined] [PortWWN= address>] [NodeWWN= Parameter ProfileName (required) The name of an existing profile to which the new connection is added. (required) Properties Fabric (optional) The name of an existing fabric to associate with the connection. If the fabric but associated with a specific bay. Speed (optional) The port speed of the connection port. Valid values include "Auto", "1Gb", "2Gb", "4Gb", "8Gb", and "Disabled". If not specified, then the default port speed is set to "Auto". "Disabled". AddressType (optional) The source of WWN address assignments to be used during the creation of the new connection. If not specified, the default is the domain default. If "UserDefined" is specified, then both a Port WWN and Node WWN must also be specified. Valid values include "Factory-Default" and "User-Defined". PortWWN (required if AddressType is User- Defined) The user-defined Port WWN address to use for the connection. This property is required if the AddressType specified is "User-Defined". PortWWN must be NodeWWN (required if AddressType is User- Defined) The user-defined Node WWN address to use for the connection. This property is required if the AddressType specified is "User-Defined". The Examples ->add fc-connection MyNewProfile Fabric=SAN_5 ->add fc-connection MyNewProfile Fabric=SomeFabric Speed=4Gb ->add fc-connection MyNewProfile ->add fc-connection MyNewProfile AddressType=Factory- Default
name is not specified, then the connection will be marked as “Unassigned”
Speed restrictions:
For the HP 4Gb VC-FC Module and HP Virtual Connect 4Gb FC Module,
valid speed values include "Auto","1Gb","2Gb", and "4Gb", and
an unused WWN address.
NodeWWN must be an unused WWN address.
Adds a new FC SAN fabric connection to a profile
Adds a new FC SAN connection and configures the port speed
Adds a new FC SAN connection and uses the next available fabric
Adds a new FC SAN connection and uses factory-default addresses
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem