Configuring ADSL Service

24

Megabit Modem 310F and 320F User Manual

Configuring Alarms

You can configure the severity of each modem alarm, or disable alarms.

1

From the

ADSL Configuration Menu

(

page 20

), type

to select

Alarm Configuration

.

2

Type

to move to the next alarm type until you select the one you want to configure.

The following table identifies the available alarm types.

3

Press the

to toggle to the setting you want for the alarm, then press

.

The following table describes the available alarm settings. The default for each alarm is E.

Alarm Type

Description

LOF

Loss of Frame

MAR

Margin

ES

Errored Seconds

SES

Severely Errored Seconds

LOS

Loss of Signal

SELF

Self test failed

Setting

Description

E

Enables the alarm as a minor alarm.

M

Enables the alarm as a major alarm.

D

Disables the alarm.