beautypg.com

Acer 330 User Manual

Page 37

background image

Chapter 1

37

Electrostatic discharge
(ESD)

15kV (at air discharge)
8kV (at contact
discharge)

15kV (at air discharge)
8kV (at contact
discharge)

Dielectric Withstand Voltage

Primary to secondary

3000 Vac (or 4242 Vdc),
10 mA for 1 second

3000 Vac (or 4242 Vdc),
10 mA for 1 second

Leakage current

0.25 mA max. (@ 254
Vac, 60Hz)

0.25 mA max. (@ 254
Vac, 60Hz)

Regulatory
Requirements

Internal filter meets:

1. FCC class B
requirements. (USA)

2. VDE 243/1991 class
B requirements.
(German)

3. CISPR 22 Class B
requirements.
(Scandinavia)

4. VCCI class II
requirements. (Japan)

Internal filter meets:

1. FCC class B
requirements. (USA)

2. VDE 243/1991 class
B requirements.
(German)

3. CISPR 22 Class B
requirements.
(Scandinavia)

4. VCCI class II
requirements. (Japan)

Power Adapter

Item

Specification