Test Cooktop Burners:
Each burner must be tested for proper lighting, proper
flame characteristics on the low setting and proper flame
characteristics on the high setting.
Test for proper ignition:
1. Push down and turn the knob to ignition symbol.
2. Verify that the ignitor/spark module clicks.
3. Once the air has been purged from the supply lines,
verify that the burner lights within four (4) seconds.
After burner lights, turn knob to the off position.
4. Test each rangetop burner in this fashion. Call Service
if any of the burners do not light.
Test flame characteristics on the low setting:
1. Push in and turn the knob to the ignition symbol until
the burner ignites.
2. Turn knob to the low setting.
3. Verify that the burner maintains a minimum, steady,
flame without going out. The flame should not lift or
blow off of the burner. It should carry over, or surround,
the entire burner.
4. Verify that the flame is the right color. It should be blue
with an inner and outer cone. “Checking Flame
Characteristics” on page 7 for more information.
5. Test each rangetop burner in this fashion. If any flame
goes out, does not carry over properly or is too large,
contact service.
Test flame characteristics on the high setting:
1. Push in and turn the knob to the ignitor symbol until the
burner ignites.
2. Turn knob to the high setting.
3. Verify that the burner maintains a steady flame. The
flame should not lift or blow off of the burner. It should
carry over, or surround, the entire burner.
4. Verify that the flame is the right color. It should be blue
with an inner and outer cone. See Figure 6: Checking
Flame Characteristics for more information.
5. Test each rangetop burner in this fashion.
If any flame does not carry over properly, adjust the bypass
jet. Return to “Convert Cooktop Valves for Propane Use”
on page 3. If any flame burns yellow, contact Service.
Dual Fuel appliance installation is complete when cor-
rect color, carryover and size are verified on each
cooktop burner.
For gas appliances, continue to “Test Broil Burner” on
page 5
Test Broil Burner
Test Ignition
Set cooking mode to Hi Broil. The burner will ignite after
30-75 seconds.
Test Flame
Verify that flame characteristics are as shown in “Checking
Flame Characteristics” on page 7. If flame characteristics
are not consistent with those in the graphic above, adjust
the flame as describerd below. Otherwise, continue to
“Test Bake Burner”.
Adjust Broil Flame (if necessary)
Adjust the air shutter to alter the flame characteristice. The
air shutter is located on the back end of the broil burner.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly
yellow, verify that the regulator is set for the correct fuel. A
retest.
Some yellow streaking is normal during the initial start-up
4-5 minutes and re-evaluate.