Safety Instructions

Preparation

Installation

Final Steps

English • 6

Your Life ...

The gas connection is located below the back panel of

the range (See Figure 4, Page 4). It is accessible

through the warming drawer access panel or from the

back of the range. To reach access panel, remove

warming drawer.

Shut off main gas supply valve before disconnecting the

old range and leave it off until the new hook-up has

been completed. Don’t forget to relight the pilot on

other gas appliances when you turn the gas back

on.

The range can be installed using rigid pipe or a CSA

International-certified flexible metal appliance connector.

If using a flexible connector, always use a new

connector.

Apply pipe joint compound or Teflon** tape appropriate

for use with LP gas and Natural gas around all male pipe

threads to prevent leaks.
If not already present, install gas shut off valve in an

easily accessible location. Make sure all users know

where and how to shut off the gas supply to the range.

Note: The installer should inform the consumer of

the location of the gas shutoff valve.

Step 7: Installation - Connect Gas Supply

Flexible Connector Method (see Figure 11, this page)

1. Install male 1/2” flare adaptor at the 1/2” NPT

internal thread of the range inlet. Use a backup

wrench on the elbow fitting to avoid damage.

2. Install male 1/2” or 3/4” flare union adapter on the

NPT internal thread of the manual shutoff valve.

3. Connect flexible metal appliance connector.

4. Make sure circuit breaker is off and then plug range

cord into electrical outlet.

5. Push range back into position insuring that range leg

slides under the anti-tip bracket. The range will sit

3/4” away from the wall when properly installed.

Note: Be careful not to crimp flexible connector!

6. Carefully tip range forward to ensure that anti-tip

bracket engages and prevents tip-over.

Important note for LP users: The range is

shipped from the factory for use with natural gas.

For use with propane (LP) gas, your range must first

be converted using the LP conversion kit.

Figure 11: Flexible Connector Method

Gas Shut-

Off Valve

Flexible

Connector

Regulator

Proceed to “Test for Gas Leaks”, next column.

Test for Gas Leaks

Leak testing is to be conducted by the installer according

to the instructions given in this section.
Turn on Gas. Apply a non-corrosive leak detection fluid

to all joints and fittings in the gas connection between

the shutoff valve and the range. Include gas fittings and

joints in the range if connections may have been

disturbed during installation. Bubbles appearing

around fittings and connections indicate a leak.
If a leak appears, turn off supply line gas shutoff valve

and tighten connections. Retest for leaks by turning on

the supply line gas shutoff valve. When leak check is

complete (no bubbles appear), test is complete. Wipe

off all detection fluid residue. Proceed to Steps 8A and

8B: Final Steps.

gas shut off valve

elbow

nipple

nipple

nipple

union

elbow

1/2” to 3/4”

gas pipe

Gas Flow to Range

Figure 12: Rigid Pipe Method

elbow:

connect to

regulator here

Rigid Pipe Method (see Figure 12, this page)

The configuration of the rigid pipe connection will vary

depending on the location of the gas pipe stub. Refer to

Figure 12 for details.

1. Make sure circuit breaker is off and then plug range

cord into electrical outlet.

2. Push range back into position ensuring that range

leg slides under the anti-tip bracket. The range will

sit 3/4” away from the wall when properly installed.

3. Carefully tip range forward to ensure that anti-tip

bracket engages and prevents tip-over.

4. Connect pipe to range at union. Access the

connection through the access panel behind the

warming drawer.

Note: Be careful not to apply pressure to warming

drawer element during rigid pipe installation.

Before you plug in an electrical cord, be sure all

controls are in the OFF position.

CAUTION

NEVER CHECK FOR LEAKS WITH A FLAME.
DO NOT CONTINUE TO THE NEXT STEP UNTIL ALL

LEAKS ARE ELIMINATED.

CAUTION

** Teflon is a registered trademark of DuPont