Safety Instructions

Preparation

Installation

Final Steps

English • 4

Your Life ...

Step 5: Prepare Electrical Connection

Install Strain Relief
Place strain relief in knockout below terminal block (See

Figure 4). Feed range cord through hole and strain relief

up to terminal block. Allow for slack in the cord between

the strain relief and terminal block. Once cord length/

slack has been adjusted, attach strain relief per

instructions included with strain relief.

TIP

The knockout panel below the terminal block can be

removed from the range to install the strain relief:

Remove knockout panel from range, install strain

relief in panel and reattach. DO NOT remove entire

range back panel.

Verify that wiring to house is adequate.
Contact your local utility company to verify that the present

electric service to your home is adequate. In some

instances, the size of the wiring to the house and service

switch must be increased to handle the electrical load

demanded by the range.
Verify that wiring inside house is adequate.
Most wiring codes require a separate circuit with separate

disconnect switch and fuses either in the main entrance

panel or in a separate switch and fuse box.
The range requires a three wire 120/240 or 120/208 volt,

30 AMP, 60 Hz AC circuit.
Most local building regulations and codes require that

electrical wiring be done by licensed electricians. Be sure

to install your range according to the electric codes in

place in your region.

General Information
Bosch

recommends that the range be installed with a

power cord set (not supplied)*. The electrical rating of the

power cord set must be 120/240 volt, 30 amperes

minimum. The power cord set shall be marked “For Use

with Ranges.” Always use a new power cord.
Note: In Canada, the range is shipped from the factory

with the range cord already installed. Proceed to “Step 7:

Installation - Connect the Gas Supply)
For installations other than those in Canada, connect the

range cord at the terminal block (See next page for

detailed instructions). Access the terminal block by

removing the cover in the lower right hand corner of the

range back panel (See Figure 4). Install the strain relief

(see next column) and the proper connector through the

knockout(s) provided. The electrical supply, including

flexible conduit or power cord, should be restricted to the

shaded areas in Figure 2 (previous page)

WARNING

The strain relief provided with your range

cord must be properly installed.

To prevent electrical shock, the grounding

prong on the range cord should not be cut or

removed under any circumstances. It must be

plugged into a matching grounding type receptacle and

connected to a correctly polarized 240- Volt circuit. If

there is any doubt as to whether the wall receptacle is

properly grounded, have it checked by a qualified

electrician.

Figure 4

Electric Connection (found

behind terminal block

cover)

Gas Connection

Feed

Range

Cord

Through

Strain

Relief in

Knockout

Panel

Here

Figure 5

WARNING

Risk of Electric Shock or Fire. Frame grounded to neutral
through a ground strap. Grounding through the neutral
conductor is prohibited for new branch-circuit installations
(1996 NEC), mobile homes, and recreational vehicles, or in an
area where local codes prohibit grounding through the neutral
conductor.
For installations where grounding through the neutral
conductor is prohibited, (a) disconnect the link from the neutral,
(b) use grounding terminal or lead to ground unit, (c) connect
neutral terminal to lead branch circuit neutral in usual manner
(when the appliance is to be connected by means of a cord kit,
use 4-conductor cord for this purpose).
Use only cord kits rated 125/250 volts (minimum), 30 amperes
and labeled “For Use with Ranges”. Strain relief provided with
cord must be installed per instructions included with cord.

5. Prepare Electrical Connection

Ranges are dual rated for use on either 120/240 VAC or

120/208 VAC. See chart below for power ratings and

circuit breaker sizes based on the supply voltage for

each model.

CAUTION:

Make certain that gas shutoff valve and all burner

controls are in the OFF position before beginning

MODEL: HDS

VOLTS

HZ

RATING

CIRCUIT

A.C.

KW

BREAKER

120/240

60

6.5

30 AMPS

120/208

60

4.8

30 AMPS

* Not needed for Canadian installations