Esc ixf2 fnc1 replacement setting, Esc ixf2, Fnc1 replacement setting – Brother TD-2120N User Manual
Page 79
P-touch Template 2.0 Command Reference
- 73 -
7. Control Command Details
ESC iXF2 FNC1 replacement setting
ASCII: ESC
i
X
F
2
n1
n2
n3
Decimal: 27
105
88
70
50
nd1
nd2
nd3
Hexadecimal: 1B 69 58 46 32 nh1 nh2 nh3
Parameters
nh1: 01h (Fixed)
nh2: 00h (Fixed)
nh3: 00h 01h
Description
Selects whether or not GS codes, which are included in barcode protocols such as GS1-128
(UCC/EAN-128), are replaced with FNC1 codes.
nh3=00h: FNC1 replacement setting OFF
nh3=01h: FNC1 replacement setting ON
This command is a static command.
Example
To disable FNC1 replacement:
ESC i X F 2 01h 00h 00h
(1Bh 69h 58h 46h 32h 01h 00h 00h)