UPC-E: 6 characters

CODABAR: 3 to 64 characters (with “A”, “B”, “C” or “D” at the beginning and end)

CODE128: 1 to 64 characters

GS1-128 (UCC/EAN-128): 1 to 64 characters

RSS-14: 3 to 15 characters (begins with “01”)

RSS Limited: 3 to 15 characters (begins with “01”; third digit is “0” or “1”)

RSS Expanded: 1 to 64 numbers or 1 to 40 letters*

* ISO646 characters can be printed.

<, ? and _>>

When trying to transfer data exceeding the ranges described above, an error will occur

while transferring. If the data that is fed does not meet the minimum limit, the bar code is

not printed. If the data exceeds the maximum limit, only the data to the maximum limit is

applied. However, if the data exceeds 64 characters, the bar code is not printed.

If a template is created in P-touch Editor with an extremely low bar code bar height, the

bars may not be printed.

● CODE39

When feeding data, the asterisks (*) at the beginning and end of the data are skipped.

● ITF (I-2/5)

The bearer bar setting specified in P-touch Editor is invalid.

● QR Code

The version setting for a QR Code specified in P-touch Editor is invalid. The version setting

must be turned off.

The linkage setting specified in P-touch Editor is invalid.

If the value specified with the QR Code version command is outside of the allowable range,

it is changed to AUTO. (MODEL1: 0 to 14, MODEL2: 0 to 40, Micro QR: 0 to 4)

● PDF417

Since the error correction levels for PDF417 specified in P-touch Editor are inconsistent

with those on the machine, the size of the bar code may change when it is printed with

P-touch Template.

The width for PDF417 specified in P-touch Editor may change from “Minimum” to “Small”.

The linkage setting specified in P-touch Editor is invalid.