INSTALLATION

GENERAL 

 

1. Follow  all  local  codes,  or  in  the  absence  of  local  codes,  follow  the  most  recent  edition  of  the 

National  Fuel  Gas  Code:  ANSI  Z223.1/NFPA  54  in  the  USA  or  CAN/CSA  B149.1  Natural  Gas, 
Propane Installation Code in Canada.  

 
2.
 All gas water heaters require careful and correct installation to ensure safe and efficient 

operation. This manual must be followed exactly. Read the “Safety Guidelines” section. 

 

3. The manifold gas pressure is preset at the factory.  It is computer controlled and should not 

need adjustment. 

 
4. Maintain proper space for servicing. Install the unit so that it can be connected or removed 

easily.  Refer to the Clearances Section on p. 9 for proper clearances.

 

 

5. The water heater must be installed in a location where the proper amount of combustible air 

will be available to it at all times without obstructions. 

 

6. The electrical connection requires a means of disconnection, to terminate power to the water 

heater for servicing and safety purposes.

 

 

7. Do not install the unit where the exhaust vent is pointing into any opening in a building or where 

the noise may disturb your neighbors. Make sure the vent termination meets the required 
distance by local code from any doorway or opening to prevent exhaust from entering a building 
(refer to p. 15). 

 

8. Particles from flour, aerosols, and other contaminants may clog the air vent or reduce the 

functions of the rotating fan and cause improper burning of the gas. Regularly ensure that the 
area around the unit is dust‐ or debris‐free; regular maintenance is recommended for these 
types of environment. 

 

9. If you will be installing the water heater in a contaminated area with a high level of dust, sand, 

flour, aerosols or other contaminants/chemicals, they can become airborne and enter and build 
up within the fan and burner causing damage to the water heater. 

 

 

10. For the 110 Indoor (T‐KJr2‐IN), 310 Indoor (T‐K4‐IN) and 510 Indoor (T‐D2‐IN) models: 

 These units may be converted to a direct‐vent (sealed combustion) appliance by installing a 

direct‐vent  conversion  kit  Part  No.  9007667005  (TK‐TV10)  which  will  bring  in  all  required 
combustible air from outside the building.  When installing the direct‐vent conversion kit, 
please follow all instructions included with the kit. 

 If the water heater is used as a direct‐vent appliance, the unit requires a 3” combustible air 

supply pipe. The intake pipe must be sealed airtight. Air supply pipe can be made of ABS,
PVC,  galvanized  steel,  corrugated  aluminum,  corrugated  stainless  steel  or  Category  III 
stainless steel. 

 Terminating the venting through a sidewall is recommended for the direct‐vent system. 

 Running the exhaust vent and the intake pipe parallel is recommended. 

 Terminating  the  exhaust  and  intake  on  the  same  wall  /  surface  is  recommended.  

Terminating  in  the  same  pressure  zone  allows  for  pressure  balancing,  which  prevents 
nuisance shutdowns. 

 

11. For the 110 Outdoor (T‐KJr2‐OS), 310 Outdoor (T‐K4‐OS) and 510 Outdoor (T‐D2‐OS) models: 

 To be installed outdoors and only in areas with mild, temperate climates. 