Troubleshooting 

37

Page

 

GENERAL 

TROUBLESHOOTING 

 

‐TEMPERATURE

 an

d

 AM

OU

NT

 OF

 HOT

 WATER

PROBLEM 

SOLUTIONS 

It takes long time to get 
hot water at the 
fixtures. 
 

 The time it takes to deliver hot water from the water heater to 

your fixtures depends on the length of piping between the two. 
The longer the distance or the bigger the pipes, the longer it will 
take to get hot water. 

 If you would like to receive hot water to your fixtures quicker, you 

may want to consider a hot water recirculation system. (p. 28) 

The water is not hot 
enough.

 

 

 Compare the flow and temperature. See the charts on p. 48‐49.  
 Check cross plumbing between cold water lines and hot water 

lines. 

 Is the gas supply valve fully open? (p. 30) 
 Is the gas line sized properly? (p. 18) 
 Is the gas supply pressure enough? (p. 19) 
 Is the set temperature set too low? (p. 33‐34) 

The water is too hot.

 

 Is the set temperature set too high? (p. 33‐34) 

The hot water is not 
available when a fixture 
is opened.

 

 

 Make sure the unit has 120 VAC / 60 Hz power supply. 
 If you are using the remote controller, is the power button turned 

on?  

 Is the gas supply valve fully open? (p. 30) 
 Is the water supply valve fully open? (p. 30) 
 Is the filter on cold water inlet clean? (p. 36) 
 Is the hot water fixture sufficiently open to draw at least 0.5 GPM 

through the water heater? (p. 33) 

 Is the unit frozen? (p. 35) 
 Is there enough gas in the tank / cylinder? (For Propane models) 

The hot water turns 
cold and stays cold.

 

 Is the flow rate enough to keep the water heater running? (p. 33) 
 If there is a recirculation system installed, does the recirculation 

line have enough check valves? (p. 28) 

 Is the gas supply valve fully open? (p. 30) 
 Is the filter on cold water inlet clean? (p. 36) 
 Are the fixtures clean of debris and obstructions? 
 Check if the flow rate is too low. (p. 33‐34) 

Fluctuation in hot water 
temperature. 

 

 Is the filter on cold water inlet clean? (p. 36) 
 Is the gas line sized properly? (p. 18) 
 Is the supply gas pressure sufficient? (p. 19) 
 Check for cross connection between cold water lines and hot water lines. 