Limited warranty, Warranty – State GTS-110-NI User Manual
Page 51

Warranty
51
│
Page
LIMITED WARRANTY
1. General terms of limited warranty:
This limited warranty gives you specific legal rights, and you may also have other rights which vary from State to State. The
manufacturer will honor the warranty to the original retail buyer at the original location only, and it is not transferable.
THIS WARRANTY COVERS ONLY FAILED MECHANICAL AND ELECTRICAL PARTS DUE TO FACTORY DEFECTS UNDER
NORMAL USAGE FOR THE PRODUCT’S INTENDED PURPOSES AND WITHIN THE APPLICABLE PERIOD SPECIFIED IN THE
FOLLOWING TABLES. ONLY DIRECT DAMAGES SHALL BE RECOVERABLE BY A CLAIMANT UNDER THIS LIMITED
WARRANTY AND, IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, BREACH OF WARRANTY, TORT
LIABILITY (INCLUDING NEGLIGENCE), STRICT LIABILITY, INDEMNITY OR OTHERWISE WILL BE LIABLE FOR ANY SPECIAL,
INCIDENTAL, OR INDIRECT CONSEQUENTIAL DAMAGES INCLUDING PROPERTY DAMAGE, PERSONAL DAMAGES, LOSS OF
USE, OR INCONVENIENCE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
2. Warranty for models: 510 (T‐D2) models
[Unit: Year]
Application
HX
(1)
Parts
Labor
Single Family
Domestic Hot
Water
No Recirculation
12
5
1
(3)
On‐Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
5
Pump Control
Timer Only
3
3
No Pump Control (24 hr.)
Commercial
or
Multi‐Family
Domestic Hot
Water
No Recirculation
5
5
1
(3)
On‐Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
Pump Control
Timer Only
3
3
No Pump Control (24 hr.)
Heating
(4)
All Types
5
5
1
(3)
Warranty for models: 110 (T‐KJr2) and 310 (T‐K4) models
[Unit: Year]
Application
HX
(1)
Parts
Labor
Single Family
Domestic Hot
Water
No Recirculation
12
5
1
(3)
On‐Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
3
3
Pump Control
Timer Only
1
1
No Pump Control (24 hr.)
Multi‐Family
Domestic Hot
Water
No Recirculation
3
3
1
(3)
On‐Demand Recirculation
(2)
w/ Standard
Recirculation
Aquastat Control
Pump Control
Timer Only
1
1
No Pump Control (24 hr.)
Heating
(4)
All Types
1
1
1
(3)
Commercial
All Types
1
1
1
(3)
(1) Heat exchanger
(2) An on‐demand recirculation system is a system that utilizes either a push‐button or other type of
manual activation (as opposed to automatic activation with a temperature sensor or timer) to
activate the circulation pump. An on‐demand recirculation system can use either the existing cold
water line as the return line or have its own dedicated return line.