Maintenance and service, Unit draining and filter cleaning – State GTS-110-NI User Manual
Page 36
Normal Operation
36
│
Page
Turn off the electrical power supply and close the manual gas shutoff valve
and the manual water control valve before servicing.
MAINTENANCE AND SERVICE
Clean the cold‐water inlet filter. (Refer to diagram below)
Be sure that all openings for combustion and ventilation air are not blocked.
The venting system should be checked annually for any leaks, corrosion, blockages or damage.
The burner should be checked annually for dust, lint, grease or dirt.
Keep the area around the water heater clear. Remove any combustible materials, gasoline or any
flammable vapors and liquids.
In accordance with all local codes and common safety practices, Water discharged from the pressure
relief vale can cause severe burns instantly from scalding. DO NOT touch the pressure relief valve.
If the relief valve discharges periodically, it may be due to thermal expansion in a closed water supply
system. Contact the water supplier or local plumbing inspector on how to correct this situation.
Visual check of burner flames (see below) through the burner window in the burner assembly located
at the middle of the water heater.
The manufacturer recommends having the unit checked once a year or as necessary by a licensed
technician. If repairs are needed, any repairs should be done by a licensed technician.
UNIT DRAINING and FILTER CLEANING
1. Close the manual gas shut off valve.
2. Turn off power to the unit and wait a couple of
seconds. Turn on again.
3. Wait 30 seconds, and then turn off power to the unit,
yet again.
4. Close the water shut off valve.
5. Open all hot water taps in the house. When the
residual water flow has ceased, close all hot water
taps.
6. Have a bucket or pan to catch the water from the
unit’s drain plugs. Unscrew the two drain plugs (Large
and small) to drain all the water out of the unit.
7. Wait a few minutes to ensure all water has
completely drained from unit.
8. Clean the filter: Check the water filter located within
the cold inlet. With a tiny brush, clean the water filter
of any debris which may have accumulated and
reinsert the filter back into the cold water inlet.
9. Securely screw the drain plugs back into place. Hand‐
tighten only.
WARNING
Drain Plug
with Filter
(Large)
Water Valve
Drain Plug
(Small)
Gas Valve
Unsatisfactory
Satisfactory
Unsatisfactory
Blue flame
Red or Yellow
flame
Flame
blowing up