beautypg.com

3 models covered, 4 standard features, 5 available options – Sterlco 2016C (Former Compact Series) User Manual

Page 7

background image

COT-C Series Hot Oil Portable Temperature Control Units

Page 7

1-3 Models Covered

This manual lists installation, operation, and maintenance
instructions for the 2016-C Series hot oil portable temperature
control unit.

Model numbers are listed on the serial tag. A model number
followed by

-Q

indicates a specially constructed unit, and not all

information in this manual may apply. Make sure that you know
the model number, serial number, and operating voltage of your
unit if you contact STERLING, Inc.

1-4 Standard Features

Off-the-shelf microprocessor-based PID temperature

controller with Process and Set Point LED readouts

Non-fused lockable rotary disconnect

Dual stage immersion heater with IEC contactors

400ºF (205ºC) maximum operating temperature

Branch fusing

System status graphic display

Pressure switch for low pump pressure shut-down

NEMA 12 electrical enclosure

UL listed subpanel

To Process pressure gauge

Independent safety thermostat

Automatic venting sequence

Positive displacement pumps capable of reversing to

evacuate the process

Low level alarm for reservoir

Easily removable panels for quick access to internal

components

Audible alarm



1-5 Available Options

Drain valve