COT-C Series Hot Oil Portable Temperature Control Units

Page 33

Figure 4

Control Panel Switches

Pump Rev|Off|Fwd

Turn the

Pump Rev|Off|Fwd

switch

to Fwd to start the pump in

the normal forward direction.

Turn the

Pump Rev|Off|Fwd

switch

to Off to stop the pump and

de-energize the controller.

!

CAUTION

Always turn to Pump Off and allow the pump to come
to a complete stop before turning to Pump Reverse.

Failure to let the pump stop before reversing may
damage the pump and drive.

Turn the

Pump Rev|Off|Fwd

switch

to Rev to start the pump in

the reverse direction. Use this feature to purge oil from the mold.


Vent Cycle Start

Press the

VENT

button to start the vent cycle timer. Use this feature

to purge air and water from the unit and process.


Mode Select

With the pump running, you can select the

AUTO

position or the

Maintained

(manual cooling) position with the

Mode Select

switch. Select

AUTO

mode to energize the controller, permitting it

to monitor and control the process. The switch automatically