beautypg.com
E-M-HP23-V2_13
Rotronic AG Bassersdorf, Switzerland
Document code
Unit
HygroPalm HP23-A / HP23-AW-A hand-held indicator:
User Guide
Instruction Manual
Document Type
Page
2 of 37
Document title
© 2009-2012; Rotronic AG E-M-HP23-V2_13
Table of contents
1
Overview ...................................................................................................................................................... 4
2
General description .................................................................................................................................... 6
2.1
Configuration software ............................................................................................................................. 6
2.2
Power supply ............................................................................................................................................ 6
2.3
Probe inputs ............................................................................................................................................. 6
2.4
Measured parameters .............................................................................................................................. 7
2.5
Calculated parameters ............................................................................................................................. 7
2.6
Alarm Indication on the display ................................................................................................................ 8
2.7
Real time clock ......................................................................................................................................... 8
2.8
Service connector..................................................................................................................................... 8
3
User configurable settings and functions ................................................................................................ 8
3.1
Factory default settings ............................................................................................................................ 8
3.2
Interaction between the HP23 and HygroClip 2 probe functions ............................................................ 10
4
Basic operation ......................................................................................................................................... 11
4.1
Display ................................................................................................................................................... 11
4.1.1
Display modes ........................................................................................................................ 11
4.1.2
Difference between Probe 1 and Probe 2 (Delta Probe) ........................................................ 12
4.1.3
User defined parameter.......................................................................................................... 12
4.2
Keypad ................................................................................................................................................... 12
4.3
ON/OFF key ........................................................................................................................................... 13
4.4
HOLD function ........................................................................................................................................ 13
4.5
Internal menu ......................................................................................................................................... 13
4.6
Frequently used settings ........................................................................................................................ 18
4.6.1
Unit system ............................................................................................................................ 18
4.6.2
Date and time ......................................................................................................................... 18
4.6.3
Select the calculated parameter for a probe input .................................................................. 18
4.6.4
Select which probe and/or parameters are shown on the display .......................................... 18
4.6.5
Set input 1 or 2 for a digital or analog probe .......................................................................... 19
4.7
Practical advice for measuring humidity ................................................................................................. 19
5
Using the HP23 functions ........................................................................................................................ 19
5.1
Data capture ........................................................................................................................................... 19
5.1.1
Capturing data ........................................................................................................................ 19
5.1.2
Viewing the captured data ...................................................................................................... 20
5.2
Data logging ........................................................................................................................................... 21
5.2.1
Logging data .......................................................................................................................... 21
5.2.2
Viewing the recorded data ...................................................................................................... 21
5.3
Calibrator function .................................................................................................................................. 22
5.3.1
Connecting a device to the HP23 ........................................................................................... 22
5.3.2
Reading measurement data ................................................................................................... 23
5.3.3
About the HP23 calibration and adjustment procedures ........................................................ 23
5.3.4
Calibration against a reference environment .......................................................................... 23
5.3.5
Calibration against a reference HygroClip 2 probe or other device ........................................ 24
5.3.6
Adjustment of humidity and temperature ................................................................................ 24
5.4
Aw Mode (HP23-AW) ............................................................................................................................. 25
5.4.1
Enabling the Aw Mode and selecting the measurement function ........................................... 25
5.4.2
Probe usage guidelines .......................................................................................................... 26
5.4.3
Using the AwQuick function ................................................................................................... 27
5.4.4
Using the AwE function .......................................................................................................... 30
6
Maintenance .............................................................................................................................................. 32
6.1
Replacing the battery ............................................................................................................................. 32
6.2
Connecting the HP23 to a PC ................................................................................................................ 32
6.3
Location of the service connector (mini USB type) ................................................................................. 32