Table 10: parameter modules - input parameters – NORD Drivesystems BU0940 User Manual
Page 40
S7 standard modules
– Supplementary manual options for NORD - Frequency Inverters
40
BU 0940 GB-3612
Name
Type
Interfac
e
Description
Module Para_...
…PPO1+…
…ACYC_…
…2
R
…2
W1
6
…2
W3
2
…Rea
d
…W1
6
…W3
2
param_read
BOOL
IN
0 = Reading of parameter value is not
requested. The parameter value at the
output "value_32" does not need to be
valid.
1 = Reading of parameter is requested. This
signal may be used as a static signal.
The output bits "valid" and " busy" are
updated together with the read
command.
X
X
value_16
WORD
IN
The 16 bit numerical value for the parameter
which is to be written is entered here. For
details of which parameters have a 16 bit
numerical value, please refer to the manual
for the frequency inverter.
X
X
value_32
WORD
IN
The 32 bit numerical value for the parameter
which is to be written is entered here. For
details of which parameters have a 32 bit
numerical value, please refer to the manual
for the frequency inverter.
X
X
param_write
BOOL
IN
0 = Writing of the parameter value is not
requested.
1 = Writing of the parameter is requested.
From this signal, the module forms a
positive flank, which means that the
signal must change from 0 -> 1 for for
the parameter to be re-written.
X
X
write_RAM
BOOL
IN
0 = Writing of the parameter value is not
requested.
1 = Writing of the parameter is requested.
From this signal, the module forms a
positive flank, which means that the
signal must change from 0 -> 1 for for
the parameter to be re-written. The
parameter is only written to the RAM.
X
X
wri
te
_
EEPR
O
M
BOOL
IN
0 = Writing of the parameter value is not
requested.
1 = Writing of the parameter is requested.
From this signal, the module forms a
positive flank, which means that the
signal must change from 0 -> 1 for for
the parameter to be re-written. The
parameter is written into the EEPROM
and cannot be written an unlimited
number of times.
X
X
Table 10: Parameter modules - Input parameters