3 Process modules
BU 0940 GB-3612
31
3.3 Process module parameters
Pos : 26 /Anl eitungen/ SPS - Baus tei ne/Pr ozessbaust eine/ Eing angs par ameter [Pr ozessbaust eine] @ 1\ mod_1338299632262_388. doc x @ 26419 @ 3 @ 1
3.3.1 Input parameters
Name
Type
Interfac
e
Description
Module
Prozess_PPO…
…1
_
1
6
…2
_
1
6
…3
_
1
6
…4
_
1
6
…2
_
3
2
…4
_
3
2
PED_FU
INT
IN
Start address of the inputs from the hardware
configurator
X
X
X
X
X
X
PAD_FU
INT
IN
Start address of the outputs from the
hardware configurator
X
X
X
X
X
X
rel_fwd
BOOL
IN
Enables the direction of rotation of the drive
for a CW rotating field
X
X
X
X
X
X
rel_rev
BOOL
IN
Enables the direction of rotation of the drive
for a CCW rotating field
X
X
X
X
X
X
volt_lock
BOOL
IN
0 = The inverter output voltage is switched
off, the FI goes into switch-on block
status.
1 = OFF 2 is cancelled; see manual for
details
X
X
X
X
X
X
fast_stop
BOOL
IN
0 = Quick stop with programmed quick stop
time; with disconnection from supply at
f=0Hz; the FI switches to starting
disabled condition.
1 = OFF 3 is cancelled; see manual for
details
X
X
X
X
X
X
fault_acc
BOOL
IN
With the switch from 0 to 1, inactive errors
are acknowledged. Note: When a digital
input has been programmed for the
"ack.fault" function, this bit must not
permanently be set to 1 via the bus
(otherwise, flank evaluation would be
prevented).
X
X
X
X
X
X
FU_Bus_in8
BOOL
IN
Only for SK 2xxE and SK 5xxE. For further
details of the function please refer to
parameter P480 in the frequency inverter
manual
X
X
X
X
FU_Bus_in9
BOOL
IN
Only for SK 2xxE and SK 5xxE. For further
details of the function please refer to
parameter P480 in the frequency inverter
manual
X
X
X
X
param_set
INT
IN
The required parameter set number is
entered here (1...4).
X
X
X
X
X
X
scal_SP1
REAL
IN
Scales the setpoint entered in parameter
P546 or P546[-01]. This parameter is
multiplied by the value from SP_1.
Example:
A value of 1.0 must be entered order to
communicate a setpoint precisely according
to the bits at input SP_1.
A value of 163.84 must be entered at input
SP_1 in order to communicate a setpoint to
the FI as a percentage.
X
X
X
X
X
X