2 structure of parameter modules, 1 parameter modules for cyclic data traffic, Structure of parameter modules – NORD Drivesystems BU0940 User Manual
Page 36: Parameter modules for cyclic data traffic, Fig. 22 parameter module "para_ppo1+2r, Table 8: example of parameter types, Table 9: assignment of function modules
S7 standard modules
– Supplementary manual options for NORD - Frequency Inverters
36
BU 0940 GB-3612
Parameter
variants
Example
Parameter
number
Index
Parameter set
Meaning
Standard
parameter
P300
300
-
-
Servo mode
Parameter Index
P475 [-02]
475
02
-
ON/OFF switching delay, digital
input 2
Parameter set-
dependant
parameter
P102
(P1
… P4)
102
-
1, 2, 3 or 4
Run-up time for parameter set 1
(or 2, 3 or 4)
Parameter set-
dependant index
parameter
P525 [-02]
(P1
… P4)
525
02
1, 2, 3 or 4
Load monitoring auxiliary value
2 for parameter set 1 (or 2, 3 or
4)
Table 8: Example of parameter types
Function module
Instance module
Write parameter
Read parameter
Para_acyc+read
Inst_FB204_R1632
-
16Bit, 32Bit
Para_acyc+W16
Inst_FB205+W16
16Bit
16Bit
Para_acyc+W32
Inst_FB206+W32
32Bit
32Bit
Table 9: Assignment of function modules
The description of the inputs and outputs is summarised in Section 4.3.
Pos : 32 /Anl eitungen/ SPS - Baus tei ne/Paramet erbaust eine/ Aufbau der Par ameter baust ei ne @ 1\ mod_1338802759671_388. doc x @ 27609 @ 233 @ 1
4.2 Structure of parameter modules
The parameter modules are listed in chronological order below.
The relevant instance modules for the function blocks, "Inst_..." provide detailed information regarding
the signal statuses between the PLC and the frequency inverter. Due to the complexity of the instance
modules they are not shown here. They are self-explanatory.
The description of the inputs and outputs is summarised in Section 4.3.
4.2.1 Parameter modules for cyclic data traffic
Fig. 22 Parameter module "Para_PPO1+2R"