Device tab – Milestone Central 3.7 User Manual
Page 42

Milestone XProtect Central 3.7; User’s Manual
Device Tab
The Client’s Navigation section will display a list of the Milestone XProtect Corporate, XProtect
Enterprise or XProtect Professional servers and associated cameras and other devices to which you
have access. Maps in the Client’s Map section may also display indicators representing cameras and
other devices (see page 34 for a complete overview of indicators).
By selecting a camera or other device in the Navigation or Map sections, you are able to view
information about the current state of the selected camera/device. Such information will be
displayed on the Information section’s Device tab.
Information is displayed in the following fields, all of which are read-only:
•
Server name: Name of the server to which the selected camera or other device is
connected.
•
Name: Name of the selected camera or other device.
•
ID: Unique ID of the selected camera or other device.
•
Enabled: Indicates whether the camera or other device is
enabled:
o
Yes (field is green)
o
No (field is red)
o
If information is not applicable, for example if there is no
connection to the server to which the camera or other
device is connected, the field will be dark gray
•
Responding: Indicates whether the camera or other device is
responding:
o
Yes (field is green)
o
No (field is red)
o
If information is not applicable, for example if there is no
connection to the server to which the camera or other
device is connected, the field will be dark gray
•
Snoozing until: If operational status information for the selected camera or other device
has been snoozed for a period of time (for information about how to snooze operational
status information, see Map Indicator Menus on page 34) this field indicates when the
period will end.
•
Alarms disabled until: If new alarms from the selected camera or other device have
been disabled for a period of time (for information about how to disable new alarms, see
Map Indicator Menus on page 34) this field indicates when the period will end.
•
Alarm management: Indicates alarm status for the selected camera or other device:
o
New Alarms (red field): Alarms in the New state are present
o
In Progress (yellow field): No new alarms, but alarms in the Open, Assigned, In
progress, Wait or On hold states are present
o
No Alarms (field is dark gray): No alarms at all, or only closed alarms (i.e. alarms
in the Closed, Auto-closed, Reject, Ignore and Resolved states), are present.
•
Motion Detection / Input signal: Field name depends on whether a camera or an input
device is selected. Indicates the date and time of the latest motion detection (for a camera)