FUTEK IHH300 (D530) Digital Display User Manual
Page 4
The torque meter can be used while the batteries are charging with no adverse effect.
The supplied power adapter is a trickle charger that will take at least 14 hours to charge a 9
volt battery. You can use any standard external quick charger to charge the 9 volt battery.
* Battery life will vary depending on quality of battery and usage-values estimates only.
Longest life will come from a lithium ion 9 volt battery.
Specifications
Range and Display:
Direct reading triple numeric LCD display with large 4 digit
primary display (5/8” high) and two additional 4 digit displays.
Maximum reading 9999.
Floating Decimal Point.
Accuracy :
:
When used with:
Smart Bench top: .5% IV from 10 – 100 % of transducer range +/- .1.
Smart Extension: 1% IV from 10 – 100% of transducer range +/- .1.
Greater accuracy may be achieved with manual calibration.
Sampling Rate:
Approx. 8,000 samples per second.
Power:
Battery: common 9 volt - ( rechargeable NiCd supplied for
convenience).
Battery life:
Up to 20 hours with standard 9 volt battery under normal
use*.
Recharging Circuit:
Internal. 110 volt input, 9 volt 300 mA output, adapter supplied
standard (center positive 2.1 mm connector).
Meter Case:
Dimensions: 7.25” long x 3.25 “ wide x 1.25” thick.
Weight: Less than 8 ounces
Stand:
Folding and adjustable bench, wall or shelf stand supplied standard.
Memory:
Up to 1,350 torque data. Includes data number, torque value and units.
Communication:
Direct to serial computer or printer.
RS232C 4800 BPS, 8, 1, n.
Communication cable and adapter supplied standard.
Operating Modes:
Track, Peak and First Peak for calibration of Micrometer (clicking)
torque wrenches.
Limits setting:
Tolerance values displayed on triple numeric display during operation.
Quick on/off with one key.
User selectable % (1-99%) with programmable target.
or
Programmable high and low values.
Tolerance prompting:
Triple lights and buzzer: Yellow (under), Green (within), Red (over)
Tolerance values displayed on triple numeric display during operation.
Display Clear Modes:
Automatic cycle complete.
Programmable timed auto reset from 1 – 9 seconds.
Manual Clear.
Filters:
5 user selectable filter settings: 170hz, 250 Hz, 500 Hz, 1500 Hz,
3600 Hz.
Transducer Selection:
Automatic “plug and play” with smart chip.
or manual “custom calibration”.
22
Table of Contents
Feature Overview....4
Keypad functions....
To change the
of operation....7
To change the
of measure....7
To turn
on/off....7
To set a new
when % is the default.....8
To
the last cleared torque....8
To
a torque value to memory....8
To view the attached
....8
To enter the
....9
To
9
To make
the default tolerance method....11
To change the
method....12
Entering the limits value....12
....12
....13
....13
....14
....15
....16
....18
....20
....20
....21
....22
mode
units
limits
target torque
recall
save
transducer information
Menu Functions
menu mode
recall memory....
high low limits
display clear (reset)
Power Standby Mode
Entering Numbers
Zeroing the Display
Torque Sensors (transducers) and Overload
Transducer Mounting Positions
Checking forAccuracy
Calibrating and bypassing the smart transducer calibration data
Selecting Custom Transducers
Printing and Sending Data
Battery and Power
Specifications
To change the
....11
% tolerance value
.5
Suggested
positions....6
To
to a printer or computer....10
To
....10
To
....10
General Operation
mounting
Quick Start....7
send memory
erase memory
set filters
3