Terminal
Block

2

1

P2

P3

P1

A

-

V

+

3 position
jumper Pin

Pin Header
(other side)

Terminal Number Terminal Block Connections

1

2

Positive (+) Analog Output Signal

Negative (-) Analog Output Signal

Terminal Configuration

Output

Jumper Settings

4-20 Milliamp

0-10 Volts DC

Connect P1 & P2 (leave P3 open) (factory
default), Max Load = 250 Ohms

Connect P2 & P3 (leave P1 open), Max Load =
500 Ohms

P2

P3

P1

P2

P3

P1

Jumper Configuration

1.6 Model AO Circuit Board Wiring

CAUTION: DISCONNECT POWER SOURCE BEFORE SERVICING.

1.7 Model FHXX and FCXX Sensor wiring

RED

Input Supply Voltage (+ 6 to 24 Vdc)

BARE

Signal Output (square wave)

BLACK

Ground (-)

RED

Signal Output (Sine wave)

BLACK

Ground (-)

Model FHXX

Model FCXX

Note: Output type - current sinking type hall effect sensor (13.5mA max).
Pull-up resistor is recommended. 5k ohm across red & bare wires.

F-2000

Page 5

Output Type:

Linear, Non-Isolated, powered loop.

Loop resistance:

250 ohm maximum for 4-20mA output
500 ohm maximum for 0-10 V DC