F-2000, Caution: disconnect power source before servicing, Model fhxx – Blue-White F-2000 – Solvent Weld PVC Tee Fitting User Manual
Page 5: Model fcxx
Terminal
Block
2
1
P2
P3
P1
A
-
V
+
3 position
jumper Pin
Pin Header
(other side)
Terminal Number Terminal Block Connections
1
2
Positive (+) Analog Output Signal
Negative (-) Analog Output Signal
Terminal Configuration
Output
Jumper Settings
4-20 Milliamp
0-10 Volts DC
Connect P1 & P2 (leave P3 open) (factory
default), Max Load = 250 Ohms
Connect P2 & P3 (leave P1 open), Max Load =
500 Ohms
P2
P3
P1
P2
P3
P1
Jumper Configuration
1.6 Model AO Circuit Board Wiring
CAUTION: DISCONNECT POWER SOURCE BEFORE SERVICING.
1.7 Model FHXX and FCXX Sensor wiring
RED
Input Supply Voltage (+ 6 to 24 Vdc)
BARE
Signal Output (square wave)
BLACK
Ground (-)
RED
Signal Output (Sine wave)
BLACK
Ground (-)
Model FHXX
Model FCXX
Note: Output type - current sinking type hall effect sensor (13.5mA max).
Pull-up resistor is recommended. 5k ohm across red & bare wires.
F-2000
Page 5
Output Type:
Linear, Non-Isolated, powered loop.
Loop resistance:
250 ohm maximum for 4-20mA output
500 ohm maximum for 0-10 V DC