F-2000, Page 2, Caution: disconnect power source before servicing – Blue-White F-2000 – Solvent Weld PVC Tee Fitting User Manual
Page 2
F-2000
Page 2
Option A: 1 / 2-14 MPT
Red Cap Plug
(for pipe fitting)
Option B: 1/2 DIA.
Knock-out
(small liquid-tight connector)
Option B: 3/4 DIA.
Knock-out
(large liquid-tight connector)
Option A: Conduit Connection
1. Remove the red cap plug.
2. Install your pipe fitting (1/2 - 14 NPT male
end).
Option B: Liquid-Tight Connections
1. Remove knock-out(s) using a screwdriver.
2. Trim edge(s) with a knife and remove sharp
edges.
3. Install the provided liquid-tight connector(s).
Notes:
For the large liquid-tight connector (3/4” Knock-out), the acceptable cable diameter is between .200 - .394 in (5.1 -
10.0 mm).
For the small liquid-tight connector (½”Knock-out), the acceptable cable diameter is between .118 - .255 in (3.0 -
6.5 mm).
Internal V
iew
1.0
F-2000 Electrical Wiring Connections
1.1 Enclosure knock-out Instructions
1.2 Optional Circuit Board Installation
1.
Carefully align optional board’s Pin
Header with the Pin Header socket
located on the main circuit board.
2.
Press firmly into place.
3.
Secure the board with the two screws
provided.
CAUTION: DISCONNECT POWER
SOURCE BEFORE SERVICING.
F-2000
Enclosure
Cover
N.C.
N.O.
C
F-2000-PC
F-2000-PB
(OPTIONAL
BOARD)
F-2000-AO
(OPTIONAL
BOARD)
F-2000-R
T
(MAIN BOARD)