MAINTENANCE

ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY
before installing, servicing or making any adjustments.

LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE
ATTEMPTING TO SERVICE.
Submersible pumps contain oil that
become pressurized and hot under normal operating conditions.

1. Submersible pump models have permanently lubricated

bearings and require no additional lubrication.

2. The pump should be inspected 3-4 times per year for

pump movement or buildup of debris on the switch or fl oat.
Reposition pump if it has moved. Remove any debris that
could interfere with the operation of the switch.

DO NOT SUBMERGE PEDESTAL MOTOR or allow motor to
be exposed to water.

3. Submersible pump may contain dielectric oil for cooling.

Dielectric oil can be harmful to the environment. Follow
state environmental laws when disposing of oil.

4. The pump motor is equipped with automatic resetting

thermal protector and may restart unexpectedly.
Protector tripping is an indication of motor overloading as
a result of operating the pump at low heads, excessively
high or low voltage, inadequate wiring, incorrect motor
conditions, or a faulty motor or pump.

TROUBLESHOOTING

DO NOT USE AN EXTENSION CORD. Extension cords could
present a safety hazard if not sized properly, become damaged or
the connection falls into the sump. If receptacle is not within reach
of the pump’s power cord, contact a qualifi ed licensed electrician
to install a new receptacle.

Symptoms

Possible Cause(s)

Suggested Remedies

Pump will not
start or run

1. Water level too low

2. Blown fuse or tripped circuit breaker

3. Low line voltage

4. Motor

5. Switch

6. Inlet screen clogged

7. Switch obstruction

1. Water must be at the appropriate level to activate switch

2. If blown, determine cause and then either replace with proper

sized fuse or reset breaker

3. Contact an electrician

4. Replace pump

5. Replace switch

6. Remove debris

7. Remove obstruction to ensure free motion of switch

Pump starts and
stops too often

1. Back-flow of water from discharge

pipe

2. Switch

3. Check valve not functioning

properly or leaking

1. Install check valve

2. Replace switch

3. Remove and examine check valve for prop er in stal la tion and

free operation. Replace check valve if necessary.

INSTALLATION MANUAL