Badger Meter Vortex Meters User Manual
Page 7
7
09-VRX-UM-00408 07/12
Upstream Obstruction
Minimum Required Straight-run Pipe
Diameters Upstream from Meter
90° Elbow
10
Two 90° Elbows, Same Plane
15
Two 90° Elbows, Diff erent Planes
20
Flow Straightener
(recommended when ever an axial swirl exists in the fl ow stream)
10
Fully Open Shut-off Valve
5
Downstream Obstruction
Minimum Required Straight-run Pipe
Diameters Downstream from Meter
Control Valve
5
TABLE 1 - MINIMUM PIPING REQUIREMENTS
NOMINAL SIZE
INCH (mm)
GALLONS PER MINUTE (gpm)
LITERS PER MINUTE (lpm)
Minimum Flow
Maximum Flow
Minimum Flow
Maximum Flow
4.0 (100)
79
635
300
2,403
6.0 (152)
180
1441
682
5,454
8.0 (203)
312
2,495
1,181
9,444
10.0 (254)
492
3,933
1,861
14,886
12.0 (305)
698
5,582
2,641
21,130
14.0 (356)
843
6,746
3,192
25,537
16.0 (406)
1,102
8,813
4,170
33,360
18.0 (457)
1,394
11,155
5,278
42,226
20.0 (508)
1,733
13,864
6,560
52,481
Based on water at 1 centistoke at 73° F, schedule 40 pipe 1 to 20 fps (0.3 to 6 mps). For reference only, consult sizing
program for temperature and pressure conditions other than those listed here.
TABLE 2 - FLOW RANGES
- BEACON Advanced Metering Analytics (AMA) (2 pages)
- GALAXY (16 pages)
- GALAXY (20 pages)
- GALAXY (28 pages)
- ORION Cellular Endpoint (2 pages)
- ORION Cellular Endpoint (32 pages)
- ORION Cellular Endpoint (80 pages)
- ORION Migratable (ME) (96 pages)
- ORION Migratable (ME) (72 pages)
- ORION Migratable (ME) (60 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (28 pages)
- ORION Classic (CE) (8 pages)
- ORION Classic (CE) (16 pages)
- ORION Classic (CE) (32 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (28 pages)
- ORION Fixed Network (SE) (4 pages)
- ORION Fixed Network (SE) (48 pages)
- ORION Migratable (ME) (48 pages)
- ORION Migratable (ME) (2 pages)
- ORION Migratable (ME) (32 pages)
- ORION Migratable (ME) (20 pages)
- E-Series Ultrasonic Meters (2 pages)
- E-Series Ultrasonic Meters (12 pages)
- M-Series M2000 (24 pages)
- M-Series M2000 (2 pages)
- M-Series M2000 (4 pages)
- M-Series M2000 (60 pages)
- M-Series M3000 (40 pages)
- M-Series M4000 (36 pages)
- M-Series M5000 (36 pages)
- M-Series M5000 (4 pages)
- M-Series Field Verification Device (24 pages)
- Recordall Disc Series Meters (4 pages)
- Recordall Turbo Series Meters (20 pages)
- Recordall Transmitter Register (RTR) (2 pages)
- Industrial Turbo (16 pages)
- Water Conditioning (16 pages)
- Recordall Compound Series Meters (2 pages)
- Recordall Compound Series Meters (20 pages)
- Recordall Compound Series Meters (16 pages)
- Remote Electronic Display (RED) (8 pages)