EcoChill

Chiller

Technical Manual 7300221 V1.1.0_02/2013

COOLING

020C

025C

030C

040C

050C

070C

080C

090C

100C

150C

200C

Cooling capacity

kW

5.70

6.00

7.50

9.60

13.70

16.80

20.80

22.50 26.90 33.40

43.70

Total input power

(°)

kW

1.85

2.05

2.50

3.30

4.10

5.00

6.50

6.80

8.60

10.20

14.10

ENERGYEFFICIENCIES

EER

W/W

3.08

2.93

3.00

2.91

3.34

3.36

3.20

3.31

3.13

3.27

3.10

ELECTRICAL DATA
Total input current

(°)

400V A

3.7

4.2

4.70

6.3

8.9

9.9

12.4

13.1

17.1

19.3

26.4

230V

9.5

10.0

13.0

16.3

N,D,

N,D,

N,D,

N,D,

N,D,

N,D,

N,D,

Maximum current (FLA)

(°)/H

400V A

6

6

6.7

8.7

11.3

13.5

16.3

17.3

22.0

26.0

34.0

230V

16.5

16.5

19.7

23.7

N,D,

N,D,

N,D,

N,D,

N,D,

N,D,

N,D,

Peak current (LRA)

(°)/H

400V A

26.5

32.5

35.7

48.7

65.3

75.3

102.3

96.3

76.0

87.0

117.0

230V

59.5

62.5

83.7

98.7

N,D,

N,D,

N,D,

N,D,

N,D,

N,D,

N,D,

COMPRESSORS (SCROLL)

Number/circuit

1/1

1/1

1/1

1/1

1/1

1/1

1/1

1/1

2/1

2/1

2/1

Input current

A

3.2

3.7

4.0

5.5

7.4

8.4

10.9

11.5

Compressors sump heater

n°xW

1x70

1x70

1x70

1x70

1x35

1x35

1x35

1x65

2X35

2X35

2X65

Capacity controls

%

1-100 1-100 1-100 1-100 1-100 1-100 1-100 1-100

0-50-100 0-50-100 0-50-100

FANS (AXIAL)

Number

1

1

1

1

2

2

2

2

2

2

2

Air flow rate

mc/h

2500

2500

3500

3500

7200

7200

7300

7200

13200

12000

12000

Input power

kW

0.085

0.085

0.14

0.14

0.28

0.28

0.28

0.28

0.6

0.6

0.6

Input current

A

0.45

0.45

0.66

0.66

1.32

1.32

1.32

1.32

2.6

2.6

2.6

REFRIGERANT CHARGE

R410A

Kg

1.250

1.300

1.560

2.00

3.480

3.790

3.730

4.700

COOLING CONNECTIONS

Suction line

Ø

15.88

15.88

15.88

15.88

22

22

22

28

28

28

35

Liquid line

Ø

9.52

9.52

12.7

12.7

15.88

15.88

15.88

15.88

15.88

15.88

15.88

NOISE DATA

Sound power

dB(A)

61.0

61.0

68.0

68.0

69.0

69.0

69.0

68.0

76.0

77.0

78.0

Sound Pressure

dB(A)

30.0

30.0

37.0

37.0

38.0

38.0

38.0

37.0

44.0

45.0

46.0

Nominal conditions reference

IN COOLING MODE

- Evaporation temperature

5 °C

- External air temperature

35 °C

Sound power

Airedale determines sound power values in
agreement with the 9614 Standard, in com-

pliance with that requested by Eurovent certi-
fication.

(1) Sound Pressure

Sound pressure measured in free field condi-
tions with reflective surface (directivity factor
Q=2) at 10mt distance from external surface of
unit, in compliance with ISO 3744 regulations.