beautypg.com

West Control Solutions KS 800 Profibus Interface Manual User Manual

Page 35

background image

Parameter- a. Configuration-Data

ComRead

(Funktionsnr: 0)

Code

Descr.

R/W

Type

Description

Range

Rem.

B2

41 ComReadBlock1

R/W

INT

Functionblocknumber for value 1

0 … 77

B

42 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 1

0 … 2999

43 ComReadBlock1

R/W

INT

Functionblocknumber for value 2

0 … 77

44 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 2

0 … 2999

45 ComReadBlock1

R/W

INT

Functionblocknumber for value 3

0 … 77

46 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 3

0 … 2999

47 ComReadBlock1

R/W

INT

Functionblocknumber for value 4

0 … 77

48 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 4

0 … 2999

49 ComReadBlock1

R/W

INT

Functionblocknumber for value 5

0 … 77

51 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 5

0 … 2999

52 ComReadBlock1

R/W

INT

Functionblocknumber for value 6

0 … 77

53 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 6

0 … 2999

54 ComReadBlock1

R/W

INT

Functionblocknumber for value 7

0 … 77

55 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 7

0 … 2999

56 ComReadBlock1

R/W

INT

Functionblocknumber for value 8

0 … 77

57 ComReadFctKey1 R/W

INT

Funktionnumber and code for value 8

0 … 2999

ComRead

(Funktionsnr: 0)

Code

Descr.

R/W

Type

Description

Range

Rem.

B2

41 ComWriteBlock1

R/W

INT

Functionblocknumber for value 1

0 … 77

B

42 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 1

0 … 2999

43 ComWriteBlock1

R/W

INT

Functionblocknumber for value 2

0 … 77

44 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 2

0 … 2999

45 ComWriteBlock1

R/W

INT

Functionblocknumber for value 3

0 … 77

46 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 3

0 … 2999

47 ComWriteBlock1

R/W

INT

Functionblocknumber for value 4

0 … 77

48 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 4

0 … 2999

49 ComWriteBlock1

R/W

INT

Functionblocknumber for value 5

0 … 77

51 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 5

0 … 2999

52 ComWriteBlock1

R/W

INT

Functionblocknumber for value 6

0 … 77

53 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 6

0 … 2999

54 ComWriteBlock1

R/W

INT

Functionblocknumber for value 7

0 … 77

55 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 7

0 … 2999

56 ComWriteBlock1

R/W

INT

Functionblocknumber for value 8

0 … 77

57 ComWriteFctKey1 R/W

INT

Funktionnumber and code for value 8

0 … 2999

Rem. B Data structure

Definition to which data an access is made, the following entries are required:

w

Function block number r ComReadBlock or ComWriteBlock

w

Function number + individual code r ComReadFctKey or ComWriteFctKey

Example::

If the Wvol value for controller 2 (controller description 1 - 8) for ComRead must be selected,

the values are composed as follows:

Functionblocknumber Controller 2 = 51

ComReadBlock = 51

Funktionnumber

Wvol

= 01

ComReadFctKey = 0132

Single-Code

Wvol

= 32

Function block protocol

35

9499 040 50511