4.7 Connector of External input/output
4.7.1 Connector specs and pin type
Pin No
Single name
Remarks
1
+12V
+12V power supply output
2
G12
Ground power supply output
3
TRG_IN
External pulse input
4
IN_COM
Universal interface of External pulse input
5
NC
(no connection)
6
NC
(no connection)
7
OUT
External pulse output
8
OUT_COM
Universal interface of External pulse output
9
NC
(no connection)
10
FG
Ground electrode of frame work
Connector type DT-326 side: 3260-10S3 (55) [HIROSE ELECTRIC CO., LTD.]
Accessory: 3240-10P-C [HIROSE ELECTRIC CO., LTD.]
4.7.2 External Pulse Input
The unit can be operated and controlled by an external signal, from either a sensor or a machine signal like
an output from a printing press, re-winder or others. This will allow the stroboscope to flash in sync with the
target object’s rotational speed.
The input signal will have the following characteristics.
Input frequency: 60 - 10,000 FPM (1 – 160 Hz)
Input pulse width: over 50us
Delay angle: 0 - 359°
(
every 1°)
Delay time: 0 - 999ms (every 1ms)
Please connect with open collector output (below 1V (ON voltage)) or no-voltage contact output
(approx. 11mA current)
4.7.3 External pulse output
The unit will also output a signal that is related to the flash rate of the unit. This signal can be used to control
additional stroboscopes so that each flashes at the same rate or to send a pulse to data collectors.
External circuit: Open collector output, Voltage below DC30V, Current below 30mA
Output pulse width: Approx. 200us
Connector of
External
input/output
3pin
4pin
+12V
Inside DT-326
Photocoupler
1k
Ω
7pin
8pin
Inside DT-326
Photocoupler
(Same as TLP127 Toshiba)
(36V)
[Output circuit]
[Output time]
[Input circuit]
Flashing
External
pulse output
Approx. 200us