Flow - Outputs Menu - Relay A 7.15
Page 121
S
H
A
R
K
MULTI-PARAMETER CONTROLLER & ANALYZER USER’S MANUAL
Flow - Outputs Menu - Relay A 7.15
DOWN
DOWN
UP
DOWN
DOWN
DOWN
DOWN
UP
DOWN
DOWN
UP
UP
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
DOWN
TO CYCLE ON
UP
NOTE
PRESS THE AND KEYS
TOGETHER TO GO IMMEDIATELY BACK TO
RUN MODE
DOWN
If you wish to change the setting, press the 
key once which will move the cursor to the first 
character of the value to be changed
Relay B can be configured for the following operations
- Response to rising or falling process values
- Adjustable on and off set-points
- Cycle on and off times
- Failsafe operation
Each function will be explained below 
The relay can be set to control either a 
RISING or FALLING process.
In a RISING process, the control relay 
will energize when the process rises 
above a set value. In this case, the ON 
set-point must be set higher than the 
OFF set-point.
In a FALLING process, the control relay 
will energize when the process falls 
below a set value. In this case, the ON 
set-point must be set lower than the 
OFF set-point. 
The RELAY ON setting is the process 
value at which the relay will energize. It 
may be set anywhere in the normal 
range of the sensor. 
RUN MODE
UP
DOWN
Use the and 
keys to change the setting
Press the key once 
which will move the cursor 
back to the RH side of the 
display.
DOWN
Press the key to accept the 
setting and move to the next setting
If you wish to change the setting, press the 
key once which will move the cursor to the first 
character of the value to be changed
UP
DOWN
Use the and 
keys to change the setting
Press the key once 
which will move the cursor 
back to the RH side of the 
display.
DOWN
Press the key to accept the 
setting and move to the next setting
If you wish to change the setting, press the 
key once which will move the cursor to the first 
character of the value to be changed
UP
DOWN
Use the and 
keys to change the setting
Press the key once 
which will move the cursor 
back to the RH side of the 
display.
RELAY OFF 65.00 >
RELAY OFF 65.0 0 >
RELAY OFF 60.0 0 >
RELAY ON 85.00 >
RELAY ON 85.0 0 >
RELAY ON 70.0 0 >
DIRECTION R ISE >
DIRECTION R ISE >
DIRECTION F ALL >
DIRECTION RISE >
RELAY B
RELAY OFF 60.00 >
RELAY B
RELAY B
RELAY B
RELAY B
RELAY B
RELAY ON 70.00 >
RELAY B
RELAY B
RELAY B
RELAY B
RELAY B
CALIBRATION
OUTPUTS
UTILITIES
DIAGNOSTICS
SETUP
TOTAL 0
DIRECTION RISE >
RELAY A
RELAY B
RELAY B
RELAY B
The RELAY OFF setting is the process 
value at which the relay will de-energize. 
The setting must be rationalized against 
the On setting. For example, in a falling 
process, the Off setting must be higher 
than the ON setting. 
The controller will not allow you to select 
the RELAY OFF value on the wrong side 
of the RELAY ON value for the selected 
direction. If the user tries to set the 
RELAY OFF on the wrong side, the 
follwowing errors will de displayed:
Error when trying to set OFF point lower 
than ON point when set to falling.
Error when trying to set OFF point higher 
than ON point when set to rising.
ON SPT < OFF SPT
FALLING PROCESS
ON SPT > OFF SPT
RISING PROCESS