Page 4 of 16

1) Start or stop data logging

• Main display: LOG

• Secondary display: FULL if the log memory is full, OFF if not

presently logging data, or ON if presently logging data.

• Press the SETUP key to step to the next menu item.

• If FULL, the ENTER key is ignored.

• If not FULL, press the ENTER key to change to data edit

mode:

- Press the

▼ or ▲ key to toggle between OFF and

START if not presently logging data, or to toggle
between ON and STOP if presently logging data.

- When START is displayed, press the ENTER key

to start data logging and exit data edit mode.

- When STOP is displayed, press the ENTER key to

stop data logging and exit data edit mode.

- When OFF or ON is displayed, press the ENTER

key to exit data edit mode without changing the
data logging operation.

• Press the MAX/MIN key to exit the SETUP menus and return

to the main display.

2) Display number of free log records or percent empty

• Main display: number of free records or percent free

• Secondary display: RECS or PCNT

• Press the ENTER key to toggle between the number of free

log records and percent free.

• Press the SETUP key to step to the next menu item.

• Press the MAX/MIN key to exit the SETUP menus and return

to the main display.

3) Select logging interval

• Main display: interval choice presently selected, one of 1, 2,

5, 10, 30 or 60 seconds.

• Secondary display: SEC

• If presently logging data, the ENTER key is ignored.

• If not presently logging data, press the ENTER key to

change to data edit mode:

- Press the

▼ key to decrease the interval

selection, cycling to 60 after 1.

- Press the

▲ key to increase the interval selection,

cycling to 1 after 60.

- Press the ENTER key to exit data edit mode.

• Press the SETUP key to step to the next menu item.

• Press the MAX/MIN key to exit the SETUP menus and return

to the main display.

4) Send logged data to the RS232 port

• Main display: SEnd