5.5 List of Display Message

Low battery warning
Temperature monitor for internal resistance, available at
Loop, PSC/PFC & RCD function. Further measurements are
suspended until the “

symbol disappears.

Measuring

Measurements in progress

Live Circuit

Live circuit warning (Continuity / Insulation Function)

PE Hi V

Caution : Presence of 100V or more at PE terminal, appears
when touching the Touch Pad

L-N >20Ω

Alert : Presence of 20Ω or more between Line - Neutral at ATT
measurement

Noise

Caution : Presence of noise in the circuit under test during ATT
measurement. ATT function should be disabled to continue
measurements.

N - PE Hi V

Caution: Presence of high voltage between NEUTRAL - EARTH
during ATT measurement. ATT function should be disabled to
continue measurements.

Uc > UL

Caution : Uc at RCD measurement is exceeding the preset UL
value (25 or 50V).

no

Error message : When on the RCD function, RCD tripped before
measuring RCD trip time. Selected IΔn value may not be
correct.
When on the LOOP, PSC/PFC function, supply may have been
interrupted.
Wiring check for LOOP, PSC/PFC function

OK

Appears when all results passed during the RCD Auto Test
function.

× NO

Appears when any results failed during the RCD Auto Test
function.

R

H

Hi, R

S

Hi

Appears when a Probe resistance of H terminal (R

H

) or of S

terminal (R

S

) at Earth measurement is exceeded the measurable

range.

No 3-phase system

Appears to indicate wrong connection at Phase Rotation check.