Loop Impedance(EN61557-3)

Volt

Operating range compliant with

EN61557-3 operating error

Maximum percentage

operating error

L-PE

0.50~1999Ω

±30%

L-N

0.50~19.99Ω

The influencing variations used for calculating the operating error are denoted as
follows;
Temperature : 0 ℃ and 35 ℃
Phase angle : At a phase angle 0° to 18°
System frequency : 49.5Hz to 50.5Hz
System voltage : 230V+10%-15%
Supply voltage : 8V to 13.8V
Harmonics : 5% of 3rd harmonic at 0° phase angle

5% of 5th harmonic at 180° phase angle

5% of 7th harmonic at 0° phase angle

D.C quantity : 0.5% of the nominal voltage

RCD(EN61557-6)

Function

Operating error of trip current

X1/2

-10%~0%

X1, X5

0%~+10%

Ramp

-10%~+10%

The influencing variations used for calculating the operating error are denoted as follows
Temperature : 0 ℃ and 35 ℃

Earth electrode Resistance (shall not exceed below) :

IΔn (mA)

Earth electrode resistance (Ω max.)

UL50V

UL25V

10

2000

2000

30

600

600

100

200

200

300

130

65

500

80

40

1000

40

20

Table.1

System voltage: 230V+10%-15%
Supply voltage : 8V to 13.8V