KYORITSU 1062 User Manual
Page 23
81
3) RANGE key
Allows the operator to select the measuring range.
Fixed ranges
: The display shows the “ R•H ” symbol.
The range increases every time this key is pressed.
AUTO range
: The display shows the “ AUTO ” symbol.
To return to the auto-ranging mode, hold down RANGE key for
more than one second.
4) HOLD key
Selects between the DATA HOLD, AUTO HOLD and PEAK HOLD functions. To cancel
functions, press this key once again.
DATA HOLD: Holds the display readings.
The display shows the “ D•H ” symbol.
AUTO HOLD: Holds the measured value when the Test leads are handled.
The display shows the “ A•H ” symbol.
PEAK HOLD: Holds the peak value.
The display shows the “ P•H ” symbol. (Model KEW1062 only)
5) LIGHT key
LIGHT key: Use to turn on the LCD backlight.
Press this key once to turn on the LCD backlight for approximately one
minute.
The LCD backlight is lit for approximately one minute.
(To postpone turned on time, press this key once again.)
To cancel the function, hold down this key for more than one second.
6) REL ∆ / % key
The instrument can calculate relative values or differences, and percentage values from the
reference measurement values.
1 : Relative Calculation
The display shows the “ ” symbol.
The sub-display shows the reference voltage value.
2 : Percentage Calculation
The display shows the “ ”, “ % ” symbol.
The sub-display shows the reference voltage value.
7) MIN/MAX key
Displays the minimum value (MIN), maximum value (MAX) and average value (AVG)
during measurement.
Pressing this key starts recording and at the same time the display shows MIN/MAX/AVG to
release AUTO POWER OFF.