KYORITSU 1062 User Manual
Page 18
76
Continuity Check
Maximum Reading 5000
Range
Resolution Range of Operation Measuring
Current
Open-loop
Voltage
Input Protective
Voltage
500Ω
0.1Ω
The buzzer turns on
for resistances lower
than 100±50Ω.
Approx.
0.5mA
<5V
1000V rms
Diode Test
Range
Resolution
Accuracy Measuring Current
(Vf=0.6V)
Open-loop
Voltage
Input Protective
Voltage
2.4V
0.0001V
1+2
Approx. 0.5mA
<5V
1000V rms
Temperature Measurement TEMP
Range
Resolution
Accuracy
Input Protective
Voltage
-200 to 1372°C
0.1°C
1%+1.5°C
1000V rms
-328 to 2501.6°F
0.1°F
1%+2.7°F
Use optional Temperature Probe: Thermocouple Type K
Capacitor Measurement
Maximum Reading 5000
Range
Resolution
Accuracy
Input Protective Voltage
5nF
0.001nF
1+5
*1
1000V rms
50nF
0.01nF
500nF
0.1nF
5μF
0.001μF
50μF
0.01μF
500μF
0.1μF
2+5
5mF
0.001mF
3+5
50mF
0.01mF
*1: Accuracy is specified after zero adjustment (capacitor).