28

Installation and Operating Instructions BM 26 A


Clamping in position on measuring tube
MS 15 /STD/…/PC/…/BT or MS 15/EXI/…/PC/…/BT

1

Limit switch clamp

2

Limit switch bracket

3 Measuring

scale

clamp

4 Measuring

tube

5

2 M4 screws (for
bracket)

6 Switching

point

centerline
Fine adjustment:
See procedure,
section 3.6

7

MS 15 /STD or /EXI
limit switch cover


MS 15/STD/…/AL/…/HT, MS 15/EXD/…/AL/…/HT, or MS 15/EXI/…/AL/…/HT

1

1 x locking screws M6
-use 3 mm Allen key

2 Limit

switch

bracket

3

Limit switch clamp

4 Measuring

tube

5 Measuring

scale

clamp

6 Switching

point

centerline
Fine adjustment:
See procedure,
section 3.6

7 Cover

lock:

M3 screw -
use 2mm Allen key

8 MS15

EXD

limit switch cover


9

Cable fitting (not
supplied by KROHNE)