1.6.5 Functional check of local level display (bar indicator only)

Step Action

Comments

1

Break the magnetic bond between the
float and the indicator bar using a bar
magnet.

The indicator bar (9*) will drop down and
disappear behind the red cover (12*) on
the front scale.

2

Retrieve the indicator the bottom of the
tube with a bar magnet. Lift up the tube.

The indicator will again magnetically bond
with the float at the correct indicated value.

3

End of the procedure.

If the indicator bar fails to bond
magnetically, please contact KROHNE for
assistance.

*See diagram in section 1.2.