Installation and Operating Instructions BM 26 A
17
Density and operating temperature limits
Float
type
Density and operating temperature limits
No.
Min. density of product
Product temperature
Min.
Max.
kg/l lbs/
ft
3
°C °F °C °F
BM 26 A / Standard versions without approvals
1 0.82
51.19
– 200
– 325
300
570
2
0.55
34.34
– 200
– 325
300
570
3 0.50
31.21
– 200
– 325
300
570
4
0.60
37.46
– 200
– 325
300
570
Instruments or approved for use in Ex hazardous zones
BM 26 A / ATEX (local indicator with electrical equipment)
1
0.82
51.19
– 40
– 40
70 … 195*
160…380*
2
0.55
34.34
– 40
– 40
70 … 195*
160…380*
3
0.50
31.21
– 40
– 40
70 … 195*
160…380*
4
0.60
37.46
– 40
– 40
70 … 195*
160…380*
* The product temperature depends on the BM 26 A ATEX temperature class (T3 … T6). See
section 7.1 for further information.
Operating pressure limits
Float type
BM 26 A
Operating pressure limits of the float
No.
Max. allowable operating pressure
At 20°C / 70°F At 100°C / 210°F At 200°C / 390°F At 300°C / 570°F
bar psig bar psig bar psig bar psig
Standard versions without approvals
1
55 800 41 600 37 535 32 465
2
23 335 12 175 10 145 9 130
3
23 335 13 190 10 145 8 115
4
55 800 31 450 24 350 19 275
Instruments approved for use in Zone 0
BM 26 A/ATEX (local indicator with electrical equipment)
1
55 800 41 600 – –
– –
2
23 335 12 175 – –
– –
3
23 335 13 190 – –
– –
4
55 800 31 450 – –
– –
Important note
Float test pressure is tested according to pressure equipment directive 97/23/EC and official
approvals.